FeedPerRevolution

Standard Word: DrillCycleFeedPerRevolution

Variable: DrillCycle.FeedPerRevolution

Type: Double

The drilling feed rate value per revolution is kept in the variable “DrillCycle.FeedPerRevolution”.Regardless of how the feed rate mode is defined in the APT/CL file (per minute or per revolution), this value is calculated per revolution and assigned to this variable.“DrillCycleFeedPerRevolution” word is created using this variable. “DrillCycle.FeedPerRevolution” variable can be used in scripts, which is defined in “Event Cycle” or “Event Cycle Start”.“DrillCycleFeedPerRevolution” word can be used inside all drilling cycle commands such as “Format Cycle Drill” or “Format Cycle Peck”.