FeedPerMinute
Standard Word: DrillCycleFeedPerMinute
Variable: DrillCycle.FeedPerMinute
Type: Double
The drilling feed rate value per minute is kept in the variable “DrillCycle.FeedPerMinute”.Regardless of how the feed rate mode is defined in the APT/CL file (per minute or per revolution), this value is calculated per minute and assigned to this variable.“DrillCycleFeedPerMinute” word is created using this variable. “DrillCycle.FeedPerMinute” variable can be used in scripts, which is defined in “Event Cycle” or “Event Cycle Start”.“DrillCycleFeedPerMinute” word can be used inside all drilling cycle commands such as “Format Cycle Drill” or “Format Cycle Peck”.